title: "Pervaporation Membrane System Schematic — asset register"
doc_type: pid-asset-register
source: "images.jpeg"
tags: [Feed Tank, Feed Temp 2, Feed Tank Vent, P, Recirculation Valve, Feed Pump, Drain Valve, Waste Bucket, Sample Port, Feed Temp 1, Feed Pressure, Pervaporation Membrane, Cooling Water Out, Vacuum Pump, Trap Valve, Trap, Vacuum Isolation Valve, Manometer, Vacuum Control Valve, Left Impinger]
summary: "This process flow schematic illustrates a pervaporation membrane system setup. A feed pump circulates liquid from a feed tank through a heat exchanger and into a pervaporation membrane module, with recirculation and sampling loops. A vacuum system, consisting of a vacuum pump, trap, and impingers, maintains the pressure gradient required for permeation across the membrane."
---

# Pervaporation Membrane System Schematic

This process flow schematic illustrates a pervaporation membrane system setup. A feed pump circulates liquid from a feed tank through a heat exchanger and into a pervaporation membrane module, with recirculation and sampling loops. A vacuum system, consisting of a vacuum pump, trap, and impingers, maintains the pressure gradient required for permeation across the membrane.

**Source:** images.jpeg · **Components:** 23 (9 equipment, 6 instrument, 8 valve)

## Equipment (9)

| Tag | Description | Details | Connects to |
|---|---|---|---|
| Feed Tank | Feed Tank | — | Feed Pump, Feed Tank Vent, Recirculation Valve, Drain Valve, Feed Temp 2 |
| Feed Pump | Pump | — | Feed Tank, Recirculation Valve, Drain Valve, Sample Port, Feed Temp 1, Cooling Water Out |
| Waste Bucket | Vessel | — | Drain Valve |
| Pervaporation Membrane | Membrane Filter | — | Feed Pressure, Feed Temp 1, Cooling Water Out, Vacuum Pump, Trap Valve, Vacuum Isolation Valve |
| Cooling Water Out | Heat Exchanger | — | Pervaporation Membrane, Feed Tank Vent, Feed Temp 2 |
| Vacuum Pump | Vacuum Pump | — | Pervaporation Membrane |
| Trap | Vessel | — | Trap Valve |
| Left Impinger | Vessel | — | Vacuum Isolation Valve, Right Impinger, Vacuum Break Valve |
| Right Impinger | Vessel | — | Vacuum Control Valve, Left Impinger, Regulator |

## Instruments (6)

| Tag | Function (ISA 5.1) | Description | Details | Connects to |
|---|---|---|---|---|
| Feed Temp 2 | T = Temperature Indicator, field-mounted | Temperature Indicator | — | Feed Tank, Cooling Water Out |
| P | P = Pressure Indicator, field-mounted | Pressure Indicator | — | Feed Tank Vent, Recirculation Valve |
| Feed Temp 1 | T = Temperature Indicator, field-mounted | Temperature Indicator | — | Feed Pump, Pervaporation Membrane |
| Feed Pressure | P = Pressure Indicator, field-mounted | Pressure Indicator | — | Pervaporation Membrane, Feed Temp 1 |
| Manometer | P = Pressure Indicator, field-mounted | Pressure Indicator | — | Vacuum Isolation Valve |
| Regulator | — | Pressure Regulator | — | Vacuum Break Valve, Right Impinger |

## Valves (8)

| Tag | Description | Details | Connects to |
|---|---|---|---|
| Feed Tank Vent | Manual Valve | — | Feed Tank, Cooling Water Out, P |
| Recirculation Valve | Manual Valve | — | Feed Tank, Feed Pump, P |
| Drain Valve | Manual Valve | — | Feed Tank, Feed Pump, Waste Bucket |
| Sample Port | Manual Valve | — | Feed Pump |
| Trap Valve | Manual Valve | — | Pervaporation Membrane, Trap, Vacuum Break Valve |
| Vacuum Isolation Valve | Manual Valve | — | Pervaporation Membrane, Manometer, Vacuum Control Valve, Left Impinger |
| Vacuum Control Valve | Manual Valve | — | Vacuum Isolation Valve, Right Impinger |
| Vacuum Break Valve | Manual Valve | — | Trap Valve, Left Impinger, Regulator |