← All documents

Pervaporation Membrane System Schematic — asset register

images.jpeg

Feed TankFeed Temp 2Feed Tank VentPRecirculation ValveFeed PumpDrain ValveWaste BucketSample PortFeed Temp 1Feed PressurePervaporation MembraneCooling Water OutVacuum PumpTrap ValveTrapVacuum Isolation ValveManometerVacuum Control ValveLeft Impinger
5 → 911 tokens

Pervaporation Membrane System Schematic

This process flow schematic illustrates a pervaporation membrane system setup. A feed pump circulates liquid from a feed tank through a heat exchanger and into a pervaporation membrane module, with recirculation and sampling loops. A vacuum system, consisting of a vacuum pump, trap, and impingers, maintains the pressure gradient required for permeation across the membrane.

Source: images.jpeg · Components: 23 (9 equipment, 6 instrument, 8 valve)

Equipment (9)

Tag Description Details Connects to
Feed Tank Feed Tank — Feed Pump, Feed Tank Vent, Recirculation Valve, Drain Valve, Feed Temp 2
Feed Pump Pump — Feed Tank, Recirculation Valve, Drain Valve, Sample Port, Feed Temp 1, Cooling Water Out
Waste Bucket Vessel — Drain Valve
Pervaporation Membrane Membrane Filter — Feed Pressure, Feed Temp 1, Cooling Water Out, Vacuum Pump, Trap Valve, Vacuum Isolation Valve
Cooling Water Out Heat Exchanger — Pervaporation Membrane, Feed Tank Vent, Feed Temp 2
Vacuum Pump Vacuum Pump — Pervaporation Membrane
Trap Vessel — Trap Valve
Left Impinger Vessel — Vacuum Isolation Valve, Right Impinger, Vacuum Break Valve
Right Impinger Vessel — Vacuum Control Valve, Left Impinger, Regulator

Instruments (6)

Tag Function (ISA 5.1) Description Details Connects to
Feed Temp 2 T = Temperature Indicator, field-mounted Temperature Indicator — Feed Tank, Cooling Water Out
P P = Pressure Indicator, field-mounted Pressure Indicator — Feed Tank Vent, Recirculation Valve
Feed Temp 1 T = Temperature Indicator, field-mounted Temperature Indicator — Feed Pump, Pervaporation Membrane
Feed Pressure P = Pressure Indicator, field-mounted Pressure Indicator — Pervaporation Membrane, Feed Temp 1
Manometer P = Pressure Indicator, field-mounted Pressure Indicator — Vacuum Isolation Valve
Regulator — Pressure Regulator — Vacuum Break Valve, Right Impinger

Valves (8)

Tag Description Details Connects to
Feed Tank Vent Manual Valve — Feed Tank, Cooling Water Out, P
Recirculation Valve Manual Valve — Feed Tank, Feed Pump, P
Drain Valve Manual Valve — Feed Tank, Feed Pump, Waste Bucket
Sample Port Manual Valve — Feed Pump
Trap Valve Manual Valve — Pervaporation Membrane, Trap, Vacuum Break Valve
Vacuum Isolation Valve Manual Valve — Pervaporation Membrane, Manometer, Vacuum Control Valve, Left Impinger
Vacuum Control Valve Manual Valve — Vacuum Isolation Valve, Right Impinger
Vacuum Break Valve Manual Valve — Trap Valve, Left Impinger, Regulator